Solar Academy
What you need, and how the three pieces fit
Most important: The panel's maximum voltage must not exceed the inverter's limit, and the battery and inverter must be the same system voltage.
Start from one day's backup energy. That decides the battery. Panels come next and have to recharge that battery. The inverter is last. The calculator uses the same steps as this page.
-
1
Know what the system is for
Size it for what must stay on, not for every socket in the building.
- Backup when the grid drops. List the appliances that have to keep running, and for how many hours. Lights, fans, and a fridge for 4 hours is a different system from air conditioning all night.
- A normal day's use. Take monthly kWh from the electricity bill and divide by 30.
You end up with kilowatt-hours, and with watts if you listed appliances. 1,000 W running for 1 hour is 1 kWh. The kilowatt-hours decide the battery. Watts are only used later, to make sure the matched inverter can run everything at once.
-
2
Choose the battery
The battery is stored energy, in kWh. It is chosen from one day's backup energy, before the panels or the inverter.
Energy you plan to use = power in kW × the backup hours the customer asks for. A LiFePO4 battery in this guide is used to 85%, so the pack you buy is larger than the energy you take out. Round up to a pack an installer stocks.
1 kW for 4 hours = 4 kWh used → 4 ÷ 0.85 ≈ 4.7 kWh LiFePO4, which rounds up to a 5.12 kWh, 25.6V pack.
A bigger battery lasts longer. It does not let you turn on more appliances at once. The panels come next.
-
3
Match the panels
Strong sun is counted as 4 hours a day, and that day has to fully recharge the battery you actually buy. This guide uses 80% system efficiency, which already allows for heat, dust, and losses.
Array (kWp) = battery kWh ÷ (4 × 0.80) = battery kWh ÷ 3.2.
A 2.56 kWh pack → 0.8 kWp. Four 200 W panels: 4 × 200 W × 4 h × 0.80 = 2.56 kWh, which fills that pack. Two 200 W panels only make 1.28 kWh.Panels only produce while the sun is on them. Night and long outages come from the battery charged earlier.
-
4
Match the inverter
The inverter is chosen after the battery and the panels. Recommend one inverter unless one unit cannot cover the job.
Backup hours do not change the inverter. Those hours already went into the battery. If a water pump or air conditioner is on the list, tell the installer: those motors surge when they start, and 20% only covers steady running. Use a pure sine wave inverter for a fridge, a computer, or an air conditioner.
If you only know daily kWh, there is no appliance list to add. Treat that energy as if it were used over about 5 hours, then apply the same 20%.
One system, in that order
1,000 W of load, 4 hours of backup. Battery, then panels, then the inverter those two define. Same method as the calculator.
- 1. Battery
- 4.7 kWh
- Rounds up to 5.12 kWh at 25.6V. Too small, and power dies before the hours are up.
- 2. Panels
- 1.6 kWp
- Four 610 W panels. Too small, and tomorrow's battery starts half empty.
- 3. Inverter
- 1.3 kW
- One 3.2 kVA inverter. Too small, and the panels are clipped.
Cable size, roof space, and motor surge still need a look on site before anyone buys hardware.
Match panels and an inverter to a known battery
Use this when the customer already has the battery. Enter that kWh.
Battery you have, or plan to buy
Enter a battery capacity greater than 0.
You need
Panels
-- kWp
Recommended
--
--
You need
Inverter
-- kW
Recommended
--
--